Features of the 4000 Series
RETRACTABLE IP42 CABLE REEL SOLUTION
- Industrial cable reel solution/retractable cable reel
- Shock resistant plastic external case
- Cable roller guide
- Ratchet stop device every 50cm – easily removable if constant recoil of cables is required
- Protection degree IP42
- Slipring with brass rings and brushes
- Working temperature: -5°C/+50°C
- Double earth contact
- Collector insulating power 2.5kv
- Available with both PVC and rubber cable
2 Core Cable Reels
4210 - Cores = 2, Cable length = 17m+1m, Rating (wound) = 0.9KW, Rating (Unwound) = 1.4KW, Cable type = PVC
4210 RNF - Cores = 2, Cable length = 12m+1m, Rating (wound) = 0.9KW, Rating (unwound) = 1.4KW, Cable type = Rubber
4215 - Cores = 2, Cable length = 15m+1m, Rating (wound) = 1.1KW, Rating (unwound) = 1.6KW, Cable type = PVC
3 Core Cable Reels
4315 - Cores = 3, Cable length = 14m+1m, Rating (wound) = 1.2KW, Rating (unwound) = 1.8KW, Cable type = PVC
4315 RNF - Cores = 3, Cable length = 9m+1m, Rating (wound) = 1.2KW, Rating (unwound) = 1.8KW, Cable type = Rubber
4325 - Cores = 3, Cable length = 9m+1m, Rating (wound) = 1.9KW, Rating (unwound) = 2.5KW, Cable type = PVC
4325/15 - Cores = 3, Cable length = 14m+1m, Rating (wound) = 1.9KW, Rating (unwound) = 2.5KW, Cable type = PVC
4325 RNF - Cores = 3, Cable length = 7m+1m, Rating (wound) = 1.9KW, Rating (unwound) = 2.5KW, Cable type = Rubber
4 Core Cable Reels
4415 - Cores = 4, Cable length = 10m+1m, Rating (wound) = 1.4KW, Rating (unwound) = 1.9KW, Cable type = PVC
4415 RNF - Cores = 4, Cable length = 8m+1m, Rating (wound) = 1.4KW, Rating (unwound) = 1.9KW, Cable type = Rubber
4425 - Cores = 4, Cable length = 8m+1m, Rating (wound) = 2.0KW, Rating (unwound) = 2.7KW, Cable type = PVC
4425 RNF - Cores = 4, Cable length = 5m+1m, Rating (wound) = 2.0KW, Rating (unwound) = 2.7KW, Cable type = Rubber
5 Core Cable Reels
4510 - Cores = 5, Cable length = 10.5m+1m, Rating (wound) = 1.0KW, Rating (unwound) = 1.5KW, Cable type = PVC
4515 - Cores = 5, Cable length = 8m+1m, Rating (wound) = 1.4KW, Rating (unwound) = 1.9KW, Cable type = PVC
4515 RNF - Cores = 5, Cable length = 7m+1m, Rating (wound) = 1.4KW, Rating (unwound) = 1.9KW, Cable type = Rubber
OPTIONAL EXTRAS
949/804-4000 – Essential for ceiling mounting, an optional device to make the bracket fixed instead of swivel